Gocator Line Profile Sensors: User Manual
Gocator Web Interface • 220
Parameter Description
Reference Regions The algorithm uses the Reference Regions option to calculate the Z position of the hole. It is
typically used in cases where the surface around the hole is not flat.
When this option is set to Autoset, the algorithm automatically determines the reference
region. When the option is not set to Autoset, the user manually specifies the reference region.
The location of the reference region is relative to the detected center of the hole and
positioned on the nominal surface plane.
When the Reference Regions option is disabled, the tool measures the hole's Z position using
all the data in the measurement region, except for a bounding rectangular region around the
hole.
Tilt Correction Tilt of the target with respect to the alignment plane.
When this option is set to Autoset, the tool automatically detects the tilt. Otherwise, the user
must enter the angles manually. Autoset requires the measurement region to cover more areas
on the surface plane than other planes.
The results from the Plane X and Y tool can be used for angles X and Y parameters.
Decision See Decisions on page 159.
Region See Regions on page 158.
Output See Filters on page 161.
Measurement Region
The center of the hole must be inside the measurement region, even if the Partial Detection option is
enabled.