Model Laser Class Model Constant Class IMPE(mW) Class IIMPE(mw) Class INOHD(mm)
Class IINOHD
(mm)
2x20 2M
101 0.39 0.98 259 103
2x30 2M
101 0.39 0.98 259 103
3R
351 0.39 0.98 900 358
3B
2246 0.39 0.98 5759 2292
2x40 2M
101 0.39 0.98 259 103
3R
351 0.39 0.98 900 358
3B
2246 0.39 0.98 5759 2292
2x50 2M
101 0.39 0.98 259 103
3R
351 0.39 0.98 900 358
3B
2246 0.39 0.98 5759 2292
2x70 2M
98 0.39 0.98 251 100
3R
341 0.39 0.98 875 348
3B
1422 0.39 0.98 3645 1451
2x75 3B-N
8817 0.64 13777
2x80 2M
95 0.39 0.98 245 97
3R
335 0.39 0.98 859 342
3B
1031 0.39 0.98 2645 1052
To calculate the NOHDvalue for a specific laser class, use the following formula:
NOHD= Model Constant / MPE
Model Constant includes a consideration of the fan angle for the individual models.
Systems Sold or Used in the USA
Systems that incorporate laser components or laser products manufactured by LMI Technologies
require certification by the FDA.
Customers are responsible for achieving and maintaining this certification.
Customers are advised to obtain the information booklet Regulations for the Administration and
Enforcement of the Radiation Control for Health and Safety Act of 1968: HHS Publication FDA 88-8035.
This publication, containing the full details of laser safety requirements, can be obtained directly from
the FDA, or downloaded from their web site at http://www.fda.gov/cdrh.
Electrical Safety
Failure to follow the guidelines described in this section may result in electrical shock or
equipment damage.

Table of Contents