EasyManua.ls Logo

LMI Technologies Gocator Series - Restore; Restore Factory

Default Icon
533 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Gocator Line Profile Sensors: User Manual
Protocols 373
Restore
The Restore command uploads a backup file to the connected sensor and then restores all sensor files
from the backup.
The sensor must be reset or power-cycled before the restore operation can be completed.
Field Type Offset Description
length 32u 0 Command size including this field, in bytes.
id 16u 4 Command identifier (0x1014).
length 32u 6 Data length.
data[length] byte 10 Data content.
Command
Field Type Offset Description
length 32u 0 Reply size including this field, in bytes.
id 16u 4 Reply identifier (0x1014).
status 32s 6
Reply status. For a list of status codes, see Commands on page
350.
Reply
Restore Factory
The Restore Factory command restores the connected sensor to factory default settings.
The command erases the non-volatile memory of the main device.
This command has no effect on connected Buddy sensors.
Note that the sensor must be reset or power-cycled before the factory restore operation can be
completed.
Field Type Offset Description
length 32u 0 Command size including this field, in bytes.
id 16u 4 Command identifier (0x4301).
resetIp 8u 6 Specifies whether IPaddress should be restored to default:
0 Do not reset IP
1 Reset IP
Command
Field Type Offset Description
length 32u 0 Reply size including this field, in bytes.
id 16u 4 Reply identifier (0x4301).
status 32s 6
Reply status. For a list of status codes, see Commands on page
350.
Reply

Table of Contents