Gocator Line Profile Sensors: User Manual
Gocator Web Interface 204
Parameter Description
Asymmetry Detection
Resolves the orientation of an object over 360 degrees. The
possible values are:
0 None
1 Along Major Axis
2 Along Minor Axis
This setting is only visible if Rotation is checked.
Decision See Decisions on page 159.
Region See Regions on page 158.
Output See Filters on page 161.
Countersunk Hole
The Countersunk Hole tool locates a countersunk circular opening within a region of interest on the
surface and provides measurements to evaluate characteristics of countersunk holes, including the
position (X, Y, and Z)of the center of the hole, outside radius of the hole, hole bevel angle, and the depth
of the hole. The countersunk hole can be on a surface at an angle to the sensor. The tool also supports
measuring holes drilled at an angle relative to the surrounding surface.
The Countersunk Hole tool does not search
for or detect a hole. The tool expects that a
hole conforming reasonably well to the
defined parameters is present and that it is
on a sufficiently uniform background.
See Adding and Configuring a Tool on page 156 for instructions on how to add measurement tools.