Gocator Line Profile Sensors: User Manual
Gocator Web Interface • 235
Parameter Description
Nominal Stud Radius Expected radius of the stud.
Nominal Stud Length Expected length of the stud.
Base Height The height above the base surface that will be ignored when the (truncated) cone is fit to the
stud data.
Tip Height The height from the top of the surface that will be ignored when the (truncated) cone is fit to
the stud data.
Radius Offset
(Radius measurement only)
The distance from the tip of the stud from which the radius is measured.
Reference Regions The algorithm uses reference regions to calculate the base plane of the stud. Reference
regions are relative to the base of the stud.
Tilt Correction Tilt of the target with respect to the alignment plane. Set to Auto-Set to have the tool
automatically detect the tilt, or enter the angles manually. Auto-Set requires the
measurement region to cover more areas on the surface plane than other planes.
The results from the Plane X and Y tool can be used for angles X and Y parameters.
Decision See Decisions on page 159.
Region See Regions on page 158.
Output See Filters on page 161.
Parameters
Measurement Region
The tip and the side of the stud must be within the measurement region.
Volume
The Volume tool determines the volume, area, and thickness of a part. Gocator compares the
measurement value with the values in Min and Max to yield a decision. For more information on
decisions, see Decisions on page 159.
See Adding and Configuring a Tool on page 156 for instructions on how to add measurement tools.
2DView
3DView