Gocator Line Profile Sensors: User Manual
Gocator Device Files • 338
Element Type Description
RegionEnabled Boolean Setting to enable/disable region.
Region
Region3D
Measurement region.
Measurements\Volume Volume tool
measurement
Volume measurement.
Measurements\Area Volume tool
measurement
Area measurement.
Measurements\Thickness Volume tool
measurement
Thickness measurement.
Element Type Description
id (attribute) 32s Measurement ID. Optional (measurement disabled if not
set).
Name String Measurement name.
Enabled Boolean
Measurement enable state:
0 – Disable
1 – Enable
HoldEnabled Boolean
Output hold enable state:
0 – Disable
1 – Enable
SmoothingEnabled Boolean
Smoothing enable state:
0 – Disable
1 – Enable
SmoothingWindow 32u Smoothing window.
Scale 64f Output scaling factor.
Offset 64f Output offset factor.
DecisionMin 64f Minimum decision threshold.
DecisionMax 64f Maximum decision threshold.
Location
(Thickness measurement only)
32s
Measurement type:
0 – Maximum
1 – Minimum
2 – 2D Centroid
3 – 3D Centroid
4 – Average
5 – Median
Volume Tool Measurement
Output
The Output element contains the following sub-elements: Ethernet, Serial, Analog, Digital0, and Digital1.
Each of these sub-elements defines the output settings for a different type of Gocator output.