Gocator Line Profile Sensors: User Manual
Specifications • 515
The Power Draw specification is based on a Master with no sensors attached. Every sensor has
its own power requirements that need to be considered when calculating total system power
requirements.
Encoder
Master 810 and 2410 support the following types of encoder signals:Single-Ended (5 VDC, 12VDC) and
Differential (5 VDC, 12 VDC).
For 5 VDC operation, pins 2 and 3 of each channel are used.
For 12 VDCoperation, pins 1 and 3 of each channel are used.
To determine how to wire a Master to an encoder, see the illustrations below.
Single-Ended 5 VDC
Single-Ended 12 VDC