Maximum Speed Vin Maximum Duty Cycle
32 kHz 3.3 V 88%
32 kHz 5 V 56%
32 kHz 7 V 44%
32 kHz 10 V 34%
At 50% duty cycle, the maximum trigger rates are as follows:
Vin Maximum Speed
3.3 V 34 kHz
5 V 34 kHz
10 V 22 kHz
Maximum Encoder Rate
On a standalone sensor, with the encoder directly wired into the I/O port or through a Master 100, the
maximum encoder rate is about 1 MHz.
For sensors connected through a Master 400 or higher, with the encoder signal supplied to the Master,
the maximum rate is about 300 kHz.
Sensor
The following sections describe the settings that are configured in the Sensor panel on the Scan page.
Active Area
Active area refers to the region within the sensor's maximum field of view that is used for laser profiling.
By default, the active area covers the sensor's entire field of view. By reducing the active area, the sensor
can operate at higher speeds.
Active area is specified in sensor coordinates,
rather than in system coordinates. As a result, if
the sensor is already alignment calibrated, press
the Acquire button to display uncalibrated data
before configuring the active area. See Coordinate
Systems on page 49 for more information on
sensor and system coordinates.