EasyManua.ls Logo

LMI Technologies Gocator Series - Custom Result Format

Default Icon
533 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Gocator Line Profile Sensors: User Manual
Protocols 426
Field Shorthand Length Description
measurement. The measurement type is the same as
defined elsewhere (see on page 387).
Id i
n
n Decimal value that represents the unique identifier of
the measurement.
ValueStart V 1 Start of measurement value.
Value v
n
n Measurement value, in decimal. The unit of the value
is measurement-specific.
DecisionStart D 1 Start of measurement decision.
Decision d
1
1 Measurement decision,
a bit mask where:
Bit 0:
1 Pass
0 Fail
Bits 1-7:
0 Measurement value OK
1 Invalid value
2 - Invalid anchor
Custom Result Format
In the custom format, you enter a format string with place holders to create a custom message. The
default format string is "%time, %value[0], %decision[0]".
Format Value Explanation
%time Timestamp
%encoder Encoder position
%frame Frame number
%value[Measurement ID] Measurement value of the specified measurement ID. The IDmust correspond to an
existing measurement.
The value output will be displayed as an integer in micrometers.
%decision[Measurement ID] Measurement decision, where the selected measurement ID must correspond to an
existing measurement.
Measurement decision is a bit mask where:
Bit 0:
1 Pass
0 Fail
Result Placeholders

Table of Contents

Related product manuals