Gocator Web Interface 219
Measurement Illustration
X
Determines the X position of the hole center.
Y
Determines the Y position of the hole center.
Z
Determines the Z position of the hole center.
Radius
Determines the radius of the hole.
Measurements
Parameter Description
Nominal Radius Expected radius of the hole.
Radius Tolerance The maximum variation from the nominal radius (+/- from the nominal radius).
Partial Detection Enable if only part of the hole is within the measurement region. If disabled, the hole must be
completely in the region of interest for results to be valid.
Depth Limit Data below this limit (relative to the surface) is excluded from the hole calculations.
Parameters