Gocator Line Profile Sensors: User Manual
Gocator Web Interface • 210
Parameter Description
Shape The shape of the countersunk hole. (See illustrations above.)
0 – Cone
1 – Counterbore
Nominal Bevel Angle
The expected bevel angle of the countersunk hole.
Nominal Outer Radius The expected outer radius of the countersunk hole.
Nominal Inner Radius The expected inner radius of the countersunk hole.
Bevel Radius Offset The offset, relative to the surface that the countersunk hole is
on, at which the bevel radius will be measured.
Curved Surface Whether the surface that the countersunk hole is on is curved.
When this setting is enabled, specify the orientation of the
curvature in degrees in the
Curve Orientation
setting.
Reference Regions The algorithm uses the Reference Regions option to calculate the Z
position of the hole. It is typically used in cases where the surface
around the hole is not flat.
When this option is set to Autoset, the algorithm automatically
determines the reference region. When the option is not set to
Autoset, the user manually specifies the reference region. The location
of the reference region is relative to the detected center of the hole
and positioned on the nominal surface plane.
When the Reference Regions option is disabled, the tool measures the
hole's Z position using all the data in the measurement region, except
for a bounding rectangular region around the hole.
Parameters