Gocator Line Profile Sensors: User Manual
Gocator Web Interface • 196
Parameter Description
Base Type Affects detection of rising and falling edges.
When Base Type is set to Flat, both strip (raised area)and base support regions are needed.
When set to None, only a point that deviates from a smooth strip support region is needed to
find a rising or falling edge.
Location
(Strip Height, Strip X, and
Strip Z measurements only)
Specifies the strip position from which the measurements are performed.
Left - Left edge of the strip.
Right - Right edge of the strip.
Center - Center of the strip.
Left Edge
Right Edge
Specifies the features that will be considered as the strip's left and right edges. You can select
more than one condition.
Rising - Rising edge detected based on the strip edge parameters.
Falling - Falling edge detected based on the strip edge parameters.
Data end - First valid profile data point in the measurement region.
Void - Gap in the data that is larger than the maximum void threshold. Gaps connected to the
measurement region's boundary are not considered as a void.
See "Strip Start and Terminate Conditions" in the Gocator Measurement Tool Technical Manual for
the definitions of these conditions.
Select Type Specifies how a strip is selected when there are multiple strips within the measurement area.
Best - The widest strip.
Index Left - 0-based strip index, counting from left to right.
Index Right - 0-based strip index, counting from right to left.
Index 0-based strip index.
Min Height Specifies the minimum deviation from the strip base. See "Strip Step Edge Definitions" in the
Gocator Measurement Tool Technical Manual on how this parameter is used for different base
types.
Parameters