Gocator Line Profile Sensors: User Manual
Gocator Emulator 267
3. Do one of the following:
l
Click Discard to discard any unsaved changes.
l
Click Cancel to return to the main window to save your changes.
4. If you clicked Discard, navigate to the replay data to upload from the client computer and click OK.
The replay data is loaded, and anew unsaved, untitled job is created.
Replay data can be exported using the CSVformat. If you have enabled Acquire Intensity in the Scan
Mode panel on the Scan page, the exported CSVfile includes intensity data.
Surface intensity data cannot be exported to the CSVformat. It can only be exported separately
as a bitmap.
To export replay data in the CSV format:
1. Click the Export button and select Export Range Data as CSV.
In Profile mode, all data in the record buffer is exported. In Surface mode, only data at the current
replay location is exported.
Use the playback control buttons to move to a different replay location; for information on playback,
see To replay data in Playback and Measurement Simulation on page 264.
2. Optionally, convert exported data to another format using the CSVConverter Tool. For information on
this tool, see CSV Converter Tool on page 461.
The decision values in the exported data depend on the current state of the job, not the state
during recording. For example, if you record data when a measurment returns a pass decision,
change the measurement's settings so that a fail decision is returned, and then export to CSV,
you will see a fail decision in the exported data.
Recorded intensity data can be exported to a bitmap (.BMP format). Acquire Intensity must be
checked in the Scan Mode panel while data was being recorded in order to export intensity data.