Gocator Line Profile Sensors: User Manual
Gocator Device Files • 326
Element Type Description
Stream\Id 32u The stream source ID.
Measurements\CenterX Dimension tool
measurement
Center X measurement
Measurements\CenterY Dimension tool
measurement
Center Y measurement
Measurements\CenterZ Dimension tool
measurement
Center Z measurement
Measurements\Distance Dimension tool
measurement
Distance measurement
Measurements\PlaneDistance Dimension tool
measurement
Plane Distance measurement
Measurements\Height Dimension tool
measurement
Height measurement
Measurements\Length Dimension tool
measurement
Length measurement
Measurements\Width Dimension tool
measurement
Width measurement
Element Type Description
@id 32s Measurement ID. Optional (measurement disabled if not
set).
Name String Measurement name.
Enabled Boolean
Measurement enable state:
0 – Disable
1 – Enable
HoldEnabled Boolean
Output hold enable state:
0 – Disable
1 – Enable
SmoothingEnabled Boolean
Smoothing enable state:
0 – Disable
1 – Enable
SmoothingWindow 32u Smoothing window.
Scale 64f Output scaling factor.
Offset 64f Output offset factor.
DecisionMin 64f Minimum decision threshold.
DecisionMax 64f Maximum decision threshold.
Absolute
(Height, Length, and Width
measurements only)
Boolean Setting for selecting absolute or signed result.
0 – Signed
1 – Absolute
Dimension Tool Measurement