Gocator Line Profile Sensors: User Manual
Gocator Device Files 329
Element Type Description
Stream\Id 32u The stream source ID.
NominalRadius 64f Nominal radius (mm).
RadiusTolerance 64f Radius tolerance (mm).
PartialDetectionEnabled Boolean
Setting to enable/disable partial detection:
0 Disable
1 Enable
DepthLimitEnabled Boolean Setting to enable/disable depth limit:
0 Disable
1 Enable
DepthLimit 64f The depth limit relative to the surface. Data below this limit
is ignored.
RegionEnabled Boolean
Setting to enable/disable region:
0 Disable
1 Enable
Region
Region3D
Measurement region.
RefRegionsEnabled Boolean
Setting to enable/disable reference regions:
0 Disable
1 Enable
RefRegionCount 32s Count of the reference regions that are to be used.
RefRegions (Collection) Reference regions. Contains two RefRegion elements of type
SurfaceRegion2D.
AutoTiltEnabled Boolean
Setting to enable/disable tilt correction:
0 Disable
1 Enable
TiltXAngle 64f Setting for manual tilt correction angle X.
TiltYAngle 64f Setting for manual tilt correction angle Y.
Measurements\X Hole tool
measurement
X measurement
Measurements\Y Hole tool
measurement
Y measurement
Measurements\Z Hole tool
measurement
Z measurement
Measurements\Radius Hole tool
measurement
Radius measurement
Element Type Description
@id 32s Measurement ID. Optional (measurement disabled if not
set).
Hole Tool Measurement

Table of Contents