Gocator Line Profile Sensors: User Manual
Specifications 467
Repeatability Z is measured with a flat target at the middle of the measurement range. It is the 95%
confidence variation of the average height over 4096 frames. Height values are averaged over the full
FOV.
See Resolution and Accuracy on page 46 for more information.
ALL 2x00 SERIES MODELS
Scan Rate
Approx. 170Hz to 5000 Hz
Interface Gigabit Ethernet
Inputs Differential Encoder, Laser Safety Enable, Trigger
Outputs 2x Digital output, RS-485 Serial (115 kBaud), 1x Analog Output (4 - 20 mA)
Housing Gasketed aluminum enclosure, IP67
Operating Temp. 0 to 5 C
Storage Temp. -30 to 70° C
Mechanical dimensions, CD/FOV/MR, and the envelope for each sensor model are illustrated on the
following pages.
In the following drawings, the physical height dimensions of measurement ranges are reversed
compared to the logical height values returned by sensors. For an illustration of the orientation
of coordinate systems in relation to physical sensors, see the sections below for each sensor
model.

Table of Contents