Crane operation
11.2 Operation of the rated capacity limiter
11 - 22 3 112 993 en Operating manual GMK 6400
12.07.2013
After a standstill of more than 48 hours
The
Enter rigging mode submenu will open.
Display (2) will show RCL code 1100 – the cor-
responding rigging mode will be displayed.
The display (1) shows the last reeving entered,
e.g. 1.
• Enter the current rigging mode;
à p. 11 - 23.
Brightness of the
displays
The brightness of the
RCL display will adjust automatically to the ambient
lighting after turning on the ignition.
Do not cover sensor (1) and keep it clean to avoid contamination that can
affect the brightness adjustment.
You can also adjust the brightness manually;
à Adjusting display brightness,
p. 10 - 7.