Table 204. Airframe Periodic Inspection — Areas 3 and 4, Main Rotor and Upper Transmission
Deck (Cont.)
Registration No. Serial No. Helicopter Total Hours
Model InitialRMM SectionRequirement
Fire Protection
900 Examine area engine deck mounted fire/overheat detection system
detection cable, grommets, brackets, and cable connectors for
condition and security.
26−10−20
900 Examine detection control units (installed in Area 6) and electrical
connections for condition and security.
26−10−20
Hydraulic System
900 Examine hydraulic system tubes, flexible hoses, and pump case drain
hoses for leaks, indication of failure, security of connections, support,
and security of attach hardware.
29−00−00
900 Examine System 1 / System 2 manifold/reservoir for leaks, condition,
security. Do a check for correct fluid levels.
29−00−00
900 Examine System 1 / System 2 hydraulic pumps and pump case
drains for leaks, condition, and security of installation.
29−00−00
900 Examine ground support equipment (GSE) panel and interconnecting
tubes for leaks, condition, security of tube connections, support, and
security of attached hardware.
29−00−00
If optional hand pump is installed:
900 Examine hand pump for leaks, condition, and security of installation. 29−00−00
900 Examine interconnecting tubes for leaks, indication of failure, security
of connections, support, and security of attach hardware.
29−00−00
Electrical Power
900 Examine area electrical wiring and electrical component installation
for condition, support, and security of attached hardware.
98−00−00
Airframe Periodic Inspection Certification — Area 3 and 4, Main Rotor and Upper Transmission
Deck
I certify that this aircraft has been inspected in accordance with Airframe Periodic Inspection requirements and
is determined to be in an airworthy condition.
Signature
Rating Type or Certification No.
Date