CSP−900RMM−2MD Helicopters, Inc.
Rotorcraft Maintenance Manual
Page 301
Revision 17
25-60-10
SERVICING
MAINTENANCE PRACTICES
1. Servicing Instructions
A. Hoist Fluid Servicing
(Ref. Figure 1).
NOTE: With the fairings installed, a flash light
and mirror are required to verify the fluid
level through the sight gauge.
(1). Ensure fluid level is at or above
minimum level through the sight gauge
window.
(2). Add approved fluids as required
(Ref. Figure 1 and Table 1).
OIL LEVEL
SIGHT GAUGE
MINIMUM OIL LEVEL
9K25−004−A
Figure 1. Fluid Level Sight Gauge Location