CSP−900RMM−2 MD Helicopters, Inc.
Rotorcraft Maintenance Manual
Page 218
Revision 34
05-20-50
Table 204. Inspection 3 − Main Rotor and Upper Transmission Deck (Area 3 and 4) (Cont.)
Registration No. Serial No. Helicopter Total Hours
Model InitialRMM SectionRequirement
Environmental Control System
900 Inspect air vent system:
Water separator and attached ducts for condition and security
Fan, forward fan mount, and aft fan mount for condition and attach
hardware for security.
21−20−00
If optional air conditioning is installed:
900 Inspect air conditioning system:
Do a check of compressor reduction gearbox oil level
Area tubes and tube insulation for condition and security.
Evaporator and duct installation for condition and security.
CURRENT CONFIG − condenser and condenser duct installations
for condition and security.
21−50−00
Fire Protection
900 Inspect area engine deck mounted fire/overheat detection system
detection cable, grommets, brackets, and cable connectors for
condition and security.
26−10−20
900 Examine detection control units (installed in Area 6) and electrical
connections for condition and correct installation.
26−10−20
Electrical Power
900 Inspect area electrical wiring and electrical component installation for
condition, support, and security of attach hardware.
98−00−00
Touch−up all damaged paint as necessary.
Install all access panels, covers, and trim panels removed or opened for inspection.
Airframe Segmented Inspection Program Inspection 3 Certification
I certify that this aircraft has been inspected in accordance with the Airframe Segmented Inspection Program
Inspection 3 inspection requirements and is determined to be in an airworthy condition.
Signature
Rating Type or Certification No.
Date