CSP−900RMM−2 MD Helicopters, Inc.
Rotorcraft Maintenance Manual
Page 208
Revision 35
05-20-10
Table 202. Special Inspection − Calender
Registration No. Serial No. Helicopter Total Hours
Model Requirement RMM Section Initial
DAILY
Rotorcraft
900 During operation in a corrosive environment, do a rinse of the
rotorcraft (ref. the instructions in “Rotorcraft Rinse”).
CSP−SPM
20−20−00
14 DAY
Rotorcraft
900 During operation in a corrosive environment, do a wash of the
rotorcraft (ref. the instructions in “Rotorcraft Wash”).
CSP−SPM
20−20−00
6 MONTH
Main Rotor: Support, Droop Stop
900 Examine the droop stop support (ref. the instructions in “Main Rotor
Hub Assembly Inspection”).
62−20−00
1 YEAR (Do a the 1 YEAR requirements in conjunction with the Area Inspections in the ASIP)
Rotorcraft
900 Do the Visual Corrosion Guide − Periodic Inspection. CSP−SPM
20−40−00
Environmental Control System: Air−Conditioning Compressor Reduction Gearbox
Servicing (Yearly or 600 hours whichever occurs first)
900 Do the “Air Conditioning Compressor Reduction Gearbox Draining”
and “Air Conditioning Compressor Reduction Gearbox Servicing”.
12−00−00
Environmental Control System: Optional Heat/Defog System Inspection
900 Do the “Heat / Defog System Bleed Air Engine/Firewall Inspection”.
Examine bleed air engine/firewall components for general condition
and security.
21−40−00
900 Do the “Heat / Defog Tube Assemblies Inspection”, and “Under Floor
Tube Assemblies Inspection”. Examine bleed air tube installation for
evidence of bleed air line failure, general condition of insulation, and
security of supports and hardware.
21−40−00
Fire Protection: Hydrostatic Testing of Fire Extinguisher Containers
900 Make sure compliance with hydrostatic testing of fire extinguisher
containers.
26−20−20
Fire Protection: Service Life Limit of Discharge Cartridges
900 Make sure compliance with service life requirements of fire
extinguishing container primary and alternate cartridges.
26−20−20