21 Load control relay for external disconnect Page 101 of 142
MCS301 meter - product Manual 1.25 MetCom Solutions GmbH
21.1 Disconnect control by command
The integrated load control relay for external disconnect purpose offers the attached feature set:
Remote disconnect (transition b or c)
o After the relay is switched OFF the appropriate symbol for the OFF position is
displayed on the LCD
a) Remote reconnect (transition a)
o After the relay is switched ON the appropriate symbol for the ON position is
displayed on the LCD
b) Remote reconnect (transition d)
o The relay goes in the “Ready for connection” mode, the appropriate symbol on
the LCD is in the OFF position and blinking
o on the LCD display attached message is displayed:
“PRESS ON”
o Long Push button pressed
When the “PRESS ON” message appears on the LCD the customer has to
press the push button >2s to switch the relay in the ON position (transition
e). After the relay is switched ON the appropriate symbol for the ON position
is displayed on the LCD.
o Short Push button pressed
press of the push button (<2s) => the scroll mode is activated for 10s and
afterwards the message “PRESS ON” is displayed again
21.2 Disconnect control by schedule
The load control relay can be controlled using the internal clock of the meter. The reconnection
is secured in the same way as described above