MCS301 - 3ph meter Page 79 of 142
MCS301 meter - product Manual 1.25 MetCom Solutions GmbH
15.5 Log file 5 – Communication Event Log
Size of the Communication Event Log: 680 entries (rolling storage)
Below events are recorded with time and date stamp in the Communication Event Log
No Name Description
119
IF_LO_2W enabled
2 way com
munication on local port enabled
127
IF_LO_2W disabled
2 way communication on local port disabled; i.e. 1
-
way
communication enabled
140
No connection timeout
There has been no remote communication on application layer for a predefined
period of time; i.e
. meter could not be reached remotely.
141
Modem Initialization failure
Modem's response to initialization AT command(s) is invalid or ERROR or no
response received
142
SIM Card failure
SIM card is not inserted or is not recognized.
143
SIM Card ok
SIM
card has been correctly detected
144
GSM registration failure
Modem's registration on GSM network was not successful
145
GPRS registration failure
Modem's registration on GPRS network was not successful
146
PDP context established
PDP context is establ
ished
147
PDP context destroyed
PDP context is destroyed
148
PDP context failure
No Valid PDP context(s) retrieved
149
Modem SW reset
Modem restarted by SW reset
150
Modem HW reset
Mo
dem restarted by HW reset (
event is not issued after a general power
resume)
151
GSM outgoing connection
Modem is successfully connected, initiated by an outgoing call.
152
GSM incoming connection
Modem is successfully connected, initiated by an incoming call
153
GSM hang
-
up
Modem is disconnected
154
Diagnostic failure
Modem's response to diagnostic AT command(s)
is invalid
155
User initialization failure
Modem's initialization AT command(s ) is invalid.
156
Signal quality low
Signal strength too low, not known, or not detectable
157
Auto Answer N
o of calls exceed
.
Number of calls has exceeded (in mode(1) or mode(2) )
158
Local communication attempt
Indicates a successful communication on any local port has been initiated.
214
Communic
.
module removed
Indicate a removal of the communication module
215
Communi
cation module inserted
Indicate an insertion of the communication module
230
NTP synchronization
The NTP synchronisation was done successfully
231
Push failure
Nit successfully push action
255
Event log cleared
E
vent log was cleared. This is always the first entry in
the effected
event log.
Table 40: Definition of log file 5 – Communication event log
15.6 Log file 6 – Power Failure Event Log
Size of the Power Failure Event Log: 400 entries (rolling storage)
No Name Description
210
Long power failure in all phases
Duration of power failure in all phases
211
Long power failure in phase
1
Duration of power failure in phase 1
212
Long power failure in phase 2
Duration of power failure in phase 2
213
Long power failure in phase 3
Duration of power failure in phase 3
255
Event log cleared
E
vent log was cleared. This is always the first entry in
the effected
event log.
Table 41: Definition of log file 6 – Power Failure Event log