28 Client and Server architecture Page 128 of 142
MCS301 meter - product Manual 1.25 MetCom Solutions GmbH
28 Client and Server architecture
The Meter consists of one COSEM Logical Device (LD name: 0-0:42.0.0.255, SAP: 001), which
supports a
Public Client (SAP: 016)
Pre-established Client (SAP: 102)
Management Client (SAP: 001)
Reading Client (SAP: 002)
The Public client
is provided for reading meter’s general information (e.g. logical device
name). Because of lowest access level security (no security) in this type of association, this
client is permitted to reveal some limited information of meter, and is not allowed to read
metering data and performing any programming or changing in meters settings.
The Pre-established client
is intended to perform broadcasting and multicasting services
(unconfirmed) services. This type of association includes only the message exchange (not
establishing and releasing). The Pre-established can be considered as an association that
has been established previously. The Pre-established association can’t be released.
The Management client
is allowed to perform any operation on devices in point to point
connections. Both services like “Confirmed” and “Unconfirmed” service can be used.
Reading client
is for parameters and energy data reading mostly in local access.
Figure 30: Client and Server model