30 Reading and Configuration Tool Page 131 of 142
MCS301 meter - product Manual 1.25 MetCom Solutions GmbH
30 Reading and Configuration Tool
The MCS301 meter can be read out, set and parameterized via the optical and/or electrical
(RS485) interface, in accordance with the DLMS/COSEM protocol.
For this purpose, you need the Blue
2
Link readout and setting tool, which can be used to alter
and read out the meter's register and all setting parameters.
Blue
2
Link supports the following functionality:
Readout parameters
All register data
All PQ data (instantaneous, 10min interval, …)
Power outage data
All log file Log file data
All Load profile data
All connected M-Bus data
Communication module status
Meter status
Complete meter configuration
Change of meter parameters
Identification and passwords
TOU parameters
Baud rates
Parameter of display list
Pulse constants, CT/VT ratio
Input / output configuration
All Load profile parameters
All log file parameters
M-Bus parameter
Communication module parameter (GPRS)
Push mode parameters
Actions
Set time and date
Reset all counters
Reset log file parameters
Reset load profile of billing data
Reset register data
FW download of the meter application
FW download of the GPRS module
All parameters can be readout or changed remotely by using transparent GSM/GPRS or
Ethernet modules too.