23 Security functions Page 112 of 142
MCS301 meter - product Manual 1.25 MetCom Solutions GmbH
23.8 Summary of Anti Tampering features
Below Anti Tampering Features are supported by the meter:
Terminal cover opening detection
To manipulate the meter in most cases the terminal cover has to be opened. This event
can be stored with time and date stamp.
Main cover opening detection
The opening of the certified main cover is detected in the same way like the terminal
cover opening.
Magnetic manipulation detection
In case a big magnetic is used nearby the meter this event will be detected
Security concept
The tampering of the meter configuration is secured by different security levels (LLS
and/or HLS).
Log file
All tampering issues, power outages, etc. can be stored with time and date stamp in
the log file of the meter
Detection of anti-creep conditions
The duration of anti-creep conditions can be measured by the meter. This can be used
as an indication of meter manipulation.
Always run positive measurement
The meter can be configured in that way that it always the total energy is measured,
even in the case of reverse energy flow.
Reverse run detection
The reverse energy measurement can be used for detect tampering. In that case the
exact “tampered energy value” is available
Wrong password access
In case several times a wrong password is used, the communication will be blocked by
the meter until the next demand reset.