19 Inputs / Outputs Page 96 of 142
MCS301 meter - product Manual 1.25 MetCom Solutions GmbH
19.3 Outputs
The MCS301 meter is able to provide up to 6 electronic 230V, 100mA outputs placed on the
main PCB of the meter as well as 1 mechanical relay output with up to 10A.
19.3.1 Electronic outputs
The assignment of the 6 control outputs is user-configurable:
• Use as pulse outputs (S0 or 230V connection)
• Active energy +A or –A
• Reactive energy +R, -R, R1, R2, R3, R4
• Energy tariff T1-T8 indication
• Maximum demand tariff M1-M4 indication
• Controlled by Real time clock (RTC)
• Controlled by remote commands
• Alarm indication
• End of interval
• Power outage (1ph or 2-phase)
• Reverse run detection
• Error status indication
19.3.2 Mechanical relay outputs
As an additional option 1 mechanical bi-stable relays (230V, +/-20%, up to 10A) is supported.
The assignment of the control output is user-configurable:
• Energy tariff T1-T8 indication
• Maximum demand tariff M1-M4 indication
• Controlled by Real time clock (RTC)
• Controlled by remote commands
• Alarm indication
• End of interval
• Power outage (1ph or 2-phase)
• Reverse run detection
• Error status indication
• Load limitation
19.3.3 Overload Control
With the MCS301 it is possible to use up to 3 outputs for load control opportunities. After
exceeding a predefined threshold an output contact can be closed or opened.
The number of overload exceeds can be counted and/or stored in a log file. The user can define
different thresholds for the outputs.