Safety Precautions 1-9
9.
The probe sheath contains natural rubber that can cause
allergic reactions in some individuals.
10.
Do not use pre-lubricated condoms as a sheath.
Lubricant may not be compatible with the transducer
material and damage may result.
11.
Transducer damage may be caused by inappropriate gel,
detergent or cleanser:
Do not soak or saturate transducers with solutions
containing alcohol, bleach, ammonium chloride
compounds, acetone or formaldehyde.
Avoid contact with solutions or coupling gels containing
mineral oil or lanolin.
NOTE:
1.
Read the following precautions to prevent the probe from malfunction:
Clean and disinfect the probe before and after each examination.
After the examination, wipe off the ultrasound gel thoroughly.
Otherwise, the ultrasound gel may solidify and the image quality
would be degraded.
2.
Ambient conditions:
To prevent the probe from being damaged, do not use it where it will be
exposed to:
Direct sunlight or X-rays
Sudden changes in temperature
Dust
Excessive vibration
Heat generators
Use the probes under the following ambient conditions:
ambient temperature: 0 40
relative humidity:30% 85% (no condensation)
atmospheric pressure:700 hPa 1060 hPa.
Use the 4CD4s probe under the following ambient conditions:
ambient temperature: 10°C 40°C
relative humidity: 30% 85% (no condensation)
atmospheric pressure: 700 hPa 1060 hPa
3.
Repeated disinfection will eventually damage the probe, please check the
probe's performance periodically.
NOTE:
1.
The following definition of the WEEE label applies to EU
member states only: The use of this symbol indicates that this
system should not be treated as household waste. By
ensuring that this system is disposed of correctly, you will help
prevent bringing potential negative consequences to the
environment and human health. For more detailed information
with regard to returning and recycling this system, please
consult the distributor from whom you purchased the system.
2.
For system products, this label may be attached to the main unit only.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mindray M7T and is the answer not in the manual?

Mindray M7T Specifications

General IconGeneral
BrandMindray
ModelM7T
CategoryMedical Equipment
LanguageEnglish

Related product manuals