9.3.External control I/O
223
External equipment
9
Function name Description
')/2:6 In simple comparison mode or sequential mode, this is output when
GULEEOHÀRZLVH[HFXWHG
In 4-step comparator mode, this is output when the S3 conditions
DUHVDWLV¿HG
29(56 In simple comparison mode or sequential mode, this is output when
a weighing value is excessive.
In 4-step comparator mode, this is output when the S4 conditions
DUHVDWLV¿HG
2. 2XWSXWZKHQDZHLJKLQJYDOXHLV2.
UNDER 2XWSXWZKHQDZHLJKLQJYDOXHLVLQVXI¿FLHQW
0,;,1* Output when mixing operation is executed.
DISCHARGE (GATE
OPEN)
Output when discharge operation is executed.
BATCH FINISH Output when weighing operation is completed.
RECIPE FINISH Output when recipe operation is completed.
DISCHARGE FINISH Output when discharge operation is completed.
0,;,1*),1,6+ Output when mixing operation is completed.
NOZZLE
'2:1,16(57
Output when the nozzle is lowering.
DURING
MEASUREMENT
Output during weighing operation.
:(,*+,1*6(4
ERROR
Output when a sequence error occurs.
ERROR Output when an error occurs. Targeted errors are [ERROR], [ZERO
(5525@DQG>6(48(1&((5525@ĺ(UURUGLVSOD\DQG
buzzer sound").
&$3(;&(('('
ERROR
2XWSXWZKHQWKH2/RYHUORDGFRQGLWLRQVDUHVDWLV¿HG
DURING TARE 2XWSXWGXULQJWDUHZHLJKWFDQFHOODWLRQLVH[HFXWHGĺ7DUH
weight cancellation").
CENTER OF ZERO Output when in the center zero status.
GROSS DISPLAY Output when the load value display is gross weight.
NET DISPLAY Output when the load value display is net weight.
DURING HOLD 2XWSXWGXULQJKROGLQJRSHUDWLRQĺ+ROGVHWWLQJ
HOPPER1 to 20 Controls the batch gage installed at each brand hopper when
multiple hoppers are used.
Up to 20 brand hoppers can be controlled.
Application example)
6HW>+233(51R@IRUHDFKEUDQGĺ%UDQGVHWWLQJ
2. Set an I/O output that corresponds to each set hopper number.
3. Prepare an external replay, etc. to control hopper number
RXWSXWVDQGVLJQDORXWSXWVVXFKDVIXOOÀRZPHGLXPÀRZGULEEOH
ÀRZGLVFKDUJHHWFE\$1'RSHUDWLRQDQGWKXVFRQWUROOLQJWKH
batch gate installed at each hopper.