Operation and Maintenance
218
Mitel 415/430 as of R4.1
syd-0580/1.2 – R4.1 – 08.2016
FIAS interface usable again The command buffer to the PMS interface is
back below the critical limit.
Date, time critical
(positive,
with
match)
G.729 Codecs within the
licence limit again
Free G.729 codecs are once again available for
connections.
Date, time
Serious
(positive,
with
match)
Inactive radio unit port Radio unit not responding
Reason: 0: Startup running, 1: Not registered,
2: Various nodes, 3: Port not permitted, 4: Local
power supply, 5: Not connected, 6: Port reset,
7: Startup error, 8: Unknown error
Card number, port
number, radio unit
ID/reason, date, time
Serious
(negative,
with
match)
Incompatible PMS applica-
tion
The external hotel management system (PMS
application) is not suitable for communicating
with the communication server.
PMS SW version,
PMS interface ver-
sion, PMS interface
driver version, date,
time
critical
(negative,
with
match)
Incorrect or no wiring adapter
(Mitel 415/430 only)
There is no wiring adapter in the wiring adapter
slot or the wiring adapter fitted is unsuitable.
Slot number, date,
time
Critical
(without
match)
Insufficient bandwidth An user in an AIN is trying to set up a connection
and the bandwidth currently available with the
WAN link is insufficient.
Link ID, WAN link
name, available
bandwidth in Kbit/s,
date, clock
Normal
(without
match)
Internal event message desti-
nation not reachable
Local output blocked or not available Cause (0: Busy
/1: Not available
/2:(not used),
2: Barred /3: not
defined), date, time
Serious
(negative,
with
match)
Internal event message desti-
nation reachable
Local output available once again Date, time
Serious
(positive,
with
match)
Internal power supply unit
failed (Mitel 470 only)
The internal power supply unit of the communi-
cation server has failed. If the auxiliary power
supply unit has been used for redundant opera-
tion, there are no short-term limitations. If the
auxiliary power supply unit has been used to
increase the power supply, the external power
supply unit overflow must be calculated.
Date, time
Normal
(negative,
with
match)
Internal power supply unit in
service (Mitel 470 only)
The internal power supply unit of the communi-
cation server is in service.
Date, time
Normal
(positive,
with
match)
Event message Trigger condition Details
1)
Severity