Operation and Maintenance
217
Mitel 415/430 as of R4.1
syd-0580/1.2 – R4.1 – 08.2016
External auxiliary power sup-
ply failed (Mitel 470 only)
The external auxiliary power supply to the com-
munication server has failed. If the auxiliary
power supply unit has been used for redundant
operation, there are no short-term limitations. If
the auxiliary power supply unit has been used to
increase the power supply, the internal power
supply unit overflow must be calculated.
Date, time
Normal
(negative,
with
match)
External auxiliary power sup-
ply in service (Mitel 470 only)
The external auxiliary power supply to the com-
munication server is working.
Date, time
Normal
(positive,
with
match)
External event message des-
tination not reachable
External signal destination not automatically
reachable
Cause (0: Busy
/1: Not available
/2:(not used),
2: Barred /3: not
defined), date, time
Serious
(negative,
with
match)
External event message des-
tination reachable
External signal destination is now reachable Date, time
Serious
(positive,
with
match)
Fan failure (Mitel 415/430
only)
The fan is jammed or defective or the connection
is no longer making contact.
• Parameter = 0: No more fans in operation.
→
Risk of overheating: Replace defective fan.
Parameter, date,
time
critical
(negative,
with
match)
Fan failure (Mitel 470 only) The fan is jammed or defective or the connection
is no longer making contact.
• Parameter = 0: No more fans in operation.
→
Risk of overheating: System shut down
after 2 minutes.
→
Replace defective fan.
• Parameter = 1: Only one fan left in operation.
→
System still running with only one fan.
→
Replace defective fan.
Parameter, date,
time
critical
(negative,
with
match)
Fan in operation
(Mitel 415/430 only)
The fan is back in service again after a failure.
• Parameter = 0: Fan back in service again.
Parameter, date,
time
critical
(positive,
with
match)
Fan in operation (Mitel 470
only)
The fan is back in service again after a failure.
• Parameter = 0: A fan is back in service again.
• Parameter = 1: Second fan back in service
again.
Parameter, date,
time
critical
(positive,
with
match)
FIAS command buffer full The command buffer to the PMS interface is full. Date, time
critical
(negative,
with
match)
Event message Trigger condition Details
1)
Severity