90
[Change robot arm serial number] Valid only when [All Files] or [Parameter Files] is selected under [Backup].
If checked : Replaces serial number of the robot arm in the robot controller with the contents of the
mechanical parameter file to be transferred.
If not checked : A backed up file is transferred. However, the serial number of the robot arm is retained the
information inside the controller.
If communication is cancelled during a series of restore processing, please note that the origin data may
have been changed.
Precaution for Restore
When a program is running or the ALWAYS program is set up
If a batch restoration or a program restoration is executed when the program is being started, the
program will automatically be stopped.
At this time, if there is an error in the controller, the program in operation cannot be stopped, and the
message shown on the below will be displayed.
Although a restoration process can be executed even in such a case, the program currently selected
or the program that is started by ALWAYS cannot be re-written. If it is possible to remove the cause of
the error, reset the error and execute the restoration process again.
CAUTION