7 Operation
Maschinenfabrik Reinhausen GmbH 2019310 5163667/06 ENETOS
®
IM
4. Login with the user information (login = admin; password = private).
Switch the language if necessary (German/English).
Figure222: Login using a web interface
5. In the Basic settings > Network > Global menu, adjust the network set-
tings and click on the Write button.
Figure223: Network settings
6. In the Basic settings > Load/Save menu, click on the Save button to per-
manently store the settings.
7. If necessary, establish a connection to the new IP address to continue
changing settings. Click on the Help button to find out more information.
8. Attach the cable for connecting to your network.