12 Technical data
Maschinenfabrik Reinhausen GmbH 2019 3995163667/06 EN ETOS
®
IM
85 ± 0,5
63 ± 0,5
Ø 4,8
Figure262: Dimensional drawing for holes in the bushing coupling unit's retaining plate (dimen-
sions in mm)
12.10.3 Connection cable
Connection cable Bushing adapter -
bushing coupling
unit
Bushing coupling
unit - control cabi-
net
Cable type RG142/U
Length 1 m 10 m, 15 m or 20 m
based on order
Connector N connector (both
sides)
TNC connector
(one side)
Minimum permitted bending radius 50 mm
Table157: Technical data for the connection cable
12.11 Ambient conditions
Operating temperature -25...+70°C
Storage temperature -40...+85°C
Relative humidity 10...95% non-condensing
Air pressure Corresponds to 2000m above sea levelCorresponds to
2000m above sea level
Minimum spacing to other
devices/control cabinet
Top/Bottom: 88.9 mm (3.5 in; corresponds to 2 RU),
back 30 mm (1.2 in)
Table158: Permissible ambient conditions