Configure System Information 
133
 S3300 Smart Managed Pro Switch
The following table describes the non-configurable fields on the Timer Schedule Global 
Configuration page. 
Table 46.  Timer Schedule Information 
Field Description
Time Schedule 
S
tatus
Specifies if the current status of the timer schedule is active or inactive.
ID Identifies the timer schedule. The maximum number of timer schedules that can 
be created is 100.
Configure Timer Schedule 
Use this screen to configure timer schedule.
 Select the Timer Schedule Criteria:
1.  Sel
ect System > Timer Schedule > Advanced > Time Schedule Configuration. 
2.  Select th
e Timer Schedule Name to be configured. 
3.  Select th
e Timer Schedule Type of entry to be configured. The choices are Absolute or 
Periodic. The factory default is Absolute.
4.  Select th
e number of the Timer Schedule Entry to be configured or added. Select the 
option New to add a new entry.
Figure 81. Timer Schedule Criteria
Configure the Timer Schedule:
1.  Ent
er the Time Start. This is the time of day in hh:mm format when the schedule 
operation is started. This field is required.