Configuring Switching
144
S3300 Smart Managed Pro Switch
VLANs
Adding virtual LAN (VLAN) support to a Layer 2 switch offers some of the benefits of both
bridging and routing. Like a bridge, a VLAN switch forwards traffic based on the Layer 2
header, which is fast, and like a router, it partitions the network into logical segments, which
provides better administration, security, and management of multicast traffic.
By default, all ports on the switch are in the same broadcast domain. VLANs electronically
separate ports on the same switch into separate broadcast domains so that broadcast
packets are not sent to all the ports on a single switch. When you use a VLAN, users can be
grouped by logical function instead of physical location.
Each VLAN in a network has an associated VLAN ID, which displays in the IEEE 802.1Q tag
in the Layer 2 header of packets transmitted on a VLAN. An end station can omit the tag, or
the VLAN portion of the tag, in which case the first switch port to receive the packet can either
reject it or insert a tag using its default VLAN ID. A given port can handle traffic for more than
one VLAN, but it can support only one default VLAN ID.
For more information about configuring VLANs, see Virtual Local Area Network Configuration
Example on page 337.
The VLAN menu contains links described in the following sections.
Basic VLAN Configuration on page 145
VLAN Membership Configuration on page 146
VLAN Status on page 147
Port VLAN ID Configuration on page 148
MAC-Based VLAN on page 149
Protocol-Based VLAN Group Configuration on page 150
Protocol-Based VLAN Group Membership on page 151
Voice VLAN on page 151
GARP Switch Configuration on page 152
GARP Port Configuration on page 153

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NETGEAR S3300 and is the answer not in the manual?

NETGEAR S3300 Specifications

General IconGeneral
ModelNETGEAR S3300
CategorySwitch
VLAN SupportYes
Quality of Service (QoS)Yes
MAC Address Table Size16K
Uplink Ports4 x 10G SFP+
Switching Capacity128 Gbps
Forwarding Rate95.2 Mpps
LayerLayer 2+/Layer 3 Lite
ManagementWeb-based GUI, SNMP
Dimensions440 x 257 x 43 mm (17.32 x 10.12 x 1.69 in)
Jumbo Frame SupportYes
Operating Temperature0°C to 50°C (32°F to 122°F)
Storage Temperature-20°C to 70°C (-4°F to 158°F)
Humidity90% maximum relative humidity, noncondensing
Power SupplyInternal power supply
Power ConsumptionVaries by model
Ports24 or 48 x 10/100/1000BASE-T
Weight3.60 kg (7.94 lb)