EasyManua.ls Logo

NETGEAR S3300 - Page 82

NETGEAR S3300
373 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Configure System Information
82
S3300 Smart Managed Pro Switch
highest priority value will be chosen to become primary unit. If the value is set to 0, then that
switch unit never participates in Manager Election.
5. Select the Manag
ement Status. Indicates whether the selected switch is the management
unit, or a normal stacking member, or on standby.
6. Click the Appl
y button. The system prompts the administrator to confirm the management
move. Upon administrator confirmation, the entire stack, including all interfaces in the stack,
is unconfigured and reconfigured with the configuration on the new Primary Management
Unit. Configuration changes take place immediately.
7. Click the Can
cel button to cancel the configuration on the screen. The data on the screen is
reset to the latest value of the switch.
8. Click the Up
date button to update the page with the latest information on the switch.
9. Af
ter the reload is complete, all stack management capability must be performed on the new
Primary Management Unit.
The following table describes the non-configurable fields on the Stack Configuration page.
Table 24. Stack Configuration
Field Description
Hardware Management
Preference
The hardware management preference of the switch. The
hardware management preference can be disabled or unassigned.
Standby Status Identifies the switch that is configured as the standby unit. The
possibl
e values are:
Cfg
Standby. Indicates that the unit is configured as the
standby unit. The unit configured as the standby switch
becomes the stack manager if the current manager fails.
Opr
Standby. Indicates that this unit is operating as the
standby unit and the configured standby unit is not part of the
stack.
None
. The switch is not configured as the standby unit.
Switch Status Displays the status of the selected unit. The possible values are:
OK
Unsupp
orted
Code
Mismatch
Config Mismatch
Not Presen
t
S
DM Mismatch
Upda
ting Code
Basic Stack Status
The following table describes the non-configurable fields in the Basic Stack Status.

Table of Contents

Related product manuals