Configure System Information
94
S3300 Smart Managed Pro Switch
Status Operational status of the port PD detection. Possible values are:
Disabled. Indicates that no power is being delivered.
Delivering Power. Indicates that power is being drawn by the
device.
Fault. Indicates a problem with the power.
Other Fault. Indicates that the port is idle due to an error
condition.
Requesting Power. Indicates that the port is requesting power.
Searching. Indicates that the port is not in one of the other
states in this list.
Test. Indicates that the port is in Test mode.
Fault Status Describes the error description when the PSE port is in fault status.
Possible values are:
No Error. Specifies that the PSE port is not in any error state
MPS Absent. Specifies that the PSE port has detected an
absence of main power supply.
Short. Specifies that the PSE port has detected a short circuit
condition.
Overload. Specifies that the PD connected to the PSE port has
tried to provide more power than is permissible by the
hardware.
Power Denied. Specifies that the PSE port has been denied
power because of a shortage of power, or due to
administrative action.
Table 32. PoE Port Configuration Non-Configurable Data (continued)
Field Description

Table of Contents