Note 1. The value will be set in 0.01-mH increments if the resistance is less than 100 mH and 0.1-mH
increments if the resistance is 100 mH or over.
Note 2. The default setting for this parameter is the standard leakage inductance of the maximum
applicable motor.
6-1-2 Adjusting Output Torque in Vector Control
The Inverter controls the output torque of the motor according to the required load torque in vector
control. Normally, no special adjustments are required. Adjust the output torque if the maximum
torque of the motor is unavailable or improvements are required in the output torque and response in a
low-speed range.
H Adjusting the Torque Compensation Limit (n109)
Adjust the set value in n109 (torque compensation limit) if the maximum torque of the motor is insuffi-
cient or to limit the output torque to a certain degree while the motor is driven by the Inverter in vector
control.
Set the torque compensation limit in percentage based on the rated output current of the Inverter as
100%.
Compensating Torque Insufficiency
Set n109 to a larger value if the maximum torque of the motor is insufficient.
Set the value in 5% increments while checking the operation of the Inverter and motor.
Check that no overload (OL1 or OL2) is detected. If an overload is detected, decrease the set values or
consider the use of an Inverter model or motor with a higher capacity.
Limiting Output Torque
Set n109 to a smaller value if the fluctuation of the output torque is large and heavy shock is imposed
on the load, or excessive output torque is not required.
Set the value according to the condition of the load.
n109
Torque Compensation Limit Register 016D Hex Changes during
operation
No
Setting
range
0 to 250 (%) Unit of
setting
1% Default setting 150
Note 1. The Inverter in torque compensation control limits the torque at a current 1.5 times larger than
the set value.
Note 2. This parameter is enabled only when the Inverter is in vector control.
H Adjusting the Torque and Response through the V/f Pattern (n011
through n017)
The Inverter in vector control uses the V/f pattern as the reference value of the output voltage. There-
fore, by adjusting the V/f pattern the output torque and response are adjusted.
If the application requires high torque, adjust the V/f pattern so that the output voltage at the required
frequency will be high. Furthermore, energy-saving effects can be expected by decreasing the output
voltage values in the frequency ranges where high torque is not required.
n011
Maximum Frequency (FMAX) Register 010B Hex Changes during
operation
No
Setting
range
50.0 to 400.0 (Hz) Unit of
setting
0.1 Hz Default setting 60.0
Advanced Operation Chapter 6

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron SYSDRIVE 3G3MV SERIES and is the answer not in the manual?

Omron SYSDRIVE 3G3MV SERIES Specifications

General IconGeneral
ModelSYSDRIVE 3G3MV SERIES
CategoryInverter
Input Frequency50/60 Hz
Output Frequency0.1 to 400 Hz
Cooling MethodForced Air Cooling
Input Voltage200 to 240 VAC, 380 to 480 VAC
Horsepower Range0.1 to 15 HP
Power Range0.1 to 11 kW
Overload Capacity150% for 60 seconds
Braking UnitBuilt-in
Protection FunctionsOvercurrent, Overvoltage, Undervoltage, Overheat
CommunicationRS-485
Ambient Temperature-10 to 50°C
Storage Temperature-20 to 65°C
Humidity5 to 95% RH (non-condensing)
Vibration5.9 m/s² or less
Voltage Class200V, 400V