3-2 Parameter Copy and Verify Function
The Digital Operator of the 3G3MV Inverter has an EEPROM in which the set values in
all the parameters and data on the capacity and software version of the Inverter can be
stored.
By using the EEPROM, most parameter set values in the Inverter can be copied to
another Inverter.
Note In the above case, however, the Inverters must have the same power supply spec-
ification and control mode (i.e., V/f or vector control mode). Some types of param-
eter set values cannot be copied.
3-2-1 Parameter for Copying and Verifying Set Values
Use the following parameter to read, copy, and verify the set values.
Parame-
ter
Register Name Description Setting
range
Unit of
setting
Default
setting
Chan-
ges dur-
ing
opera-
tion
n176 01B0 Parame-
ter copy
and
verify
function
selection
The following items are
selectable.
rdy: Ready to accept the
next command
rEd: Reads the parameter
CPy: Copies the parameter
vFy: Verifies the parameter
vA: Displays the capacity of
the Inverter
Sno: Displays the software
version.
rdy to
Sno
--- rdy No
Preparing for Operation and Monitoring Chapter 3

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron SYSDRIVE 3G3MV SERIES and is the answer not in the manual?

Omron SYSDRIVE 3G3MV SERIES Specifications

General IconGeneral
ModelSYSDRIVE 3G3MV SERIES
CategoryInverter
Input Frequency50/60 Hz
Output Frequency0.1 to 400 Hz
Cooling MethodForced Air Cooling
Input Voltage200 to 240 VAC, 380 to 480 VAC
Horsepower Range0.1 to 15 HP
Power Range0.1 to 11 kW
Overload Capacity150% for 60 seconds
Braking UnitBuilt-in
Protection FunctionsOvercurrent, Overvoltage, Undervoltage, Overheat
CommunicationRS-485
Ambient Temperature-10 to 50°C
Storage Temperature-20 to 65°C
Humidity5 to 95% RH (non-condensing)
Vibration5.9 m/s² or less
Voltage Class200V, 400V