9-2-2 DeviceNet Communications Unit
H 3G3MV-PDRT2
This Communications Unit is required for Inverter control by DeviceNet. The following smart slave func-
tions can be used when a DeviceNet Unit is mounted to the Inverter. These functions reduce wiring re-
quirements, enable advanced diagnosis and prevention of equipment failure, and allow monitoring with
a PT or Configurator.
Refer to the User’s Manual for the DeviceNet Communications Unit for details.
Warning torque detection
Current tracing
Average power monitoring
Accumulated operating time monitoring
Contact operation count monitoring
Communication time monitoring
H External Dimensions (mm)
68
128
3
38
10.3
Specifications
Chapter 9

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron SYSDRIVE 3G3MV SERIES and is the answer not in the manual?

Omron SYSDRIVE 3G3MV SERIES Specifications

General IconGeneral
ModelSYSDRIVE 3G3MV SERIES
CategoryInverter
Input Frequency50/60 Hz
Output Frequency0.1 to 400 Hz
Cooling MethodForced Air Cooling
Input Voltage200 to 240 VAC, 380 to 480 VAC
Horsepower Range0.1 to 15 HP
Power Range0.1 to 11 kW
Overload Capacity150% for 60 seconds
Braking UnitBuilt-in
Protection FunctionsOvercurrent, Overvoltage, Undervoltage, Overheat
CommunicationRS-485
Ambient Temperature-10 to 50°C
Storage Temperature-20 to 65°C
Humidity5 to 95% RH (non-condensing)
Vibration5.9 m/s² or less
Voltage Class200V, 400V