Customers who intend to use the product described in this manual for devices or systems relating to transportation, health
care, space aviation, atomic power, electric power, or in underwater applications must first contact their OYMC
representatives or the nearest OYMC sales office.
This product has been manufactured under strict quality-control guidelines. However, if this product is to be installed in
any location where failure of this product could involve or result in a life-and-death situation or loss of human life or in a
facility where failure may cause a serious accident or physical injury, safety devices must be installed to minimize the
likelihood of any accident.
u
Quick Reference
Easily Set Application-Specific Parameters
Preset parameter defaults are available for many applications. Refer to Application Selection on
page 82.
Run a Motor of One-Frame Larger Capacity
When using this drive for variable torque loads such as fans and pumps, a motor one frame size larger can be used. Refer to C6-01: Drive Duty
Mode Selection on page 131
Know the Details of Safety Measures
The functions listed below affect the safe operation of the drive. Ensure that the settings fit the application requirements prior to operation.
Operation of digital outputs during Auto-tuning. Rotational Auto-tuning allows for normal digital output operation, while non-rotational Auto-
tuning does not allow for normal digital output operation.
Safe operations. Run by power on. Parameter setting b1-17.
LOCAL/REMOTE key effective during stop in drive mode. Parameter o2-01.
LED operator stop key priority selection. Parameter o2-02.
Enter press required after changing the keypad frequency reference. Parameter o2-05.
Operation interlock when program mode is selected. Parameter b1-08.
Replace the Drive
The removable terminal block with parameter backup function allows the transfer of parameter
settings after drive replacement. Refer to Replacing the Drive on page 269.
Drive a Synchronous PM Motor
The V1000 drive can operate synchronous PM motors. Refer to Subchart A3: Operation with
Permanent Magnet Motors on page 80.
Perform Auto-Tuning
Automatic tuning sets motor parameters. Refer to Auto-Tuning on page 87.
Check the Maintenance Period Using Drive Monitors
The maintenance period of fans and capacitors can be checked with drive monitors. Refer to Performance Life Monitors on page 266
Drive or Motor Faults are Displayed on a Digital Operator
Refer to Fault Displays, Causes, and Possible Solutions on page 230 and Refer to Alarm Codes, Causes, and Possible Solutions on page 241.
Standards Compliance
Refer to European Standards on page 382 and Refer to UL Standards on page 388.
U
L
C
R
US
LISTED
i.2 General Safety
16
SIEP C710606 20 OYMC AC Drive - V1000 User Manual
7/16/2008-13:22

Table of Contents

Other manuals for Omron V1000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron V1000 and is the answer not in the manual?

Omron V1000 Specifications

General IconGeneral
Cooling MethodFan cooling
Enclosure RatingIP20
CommunicationModbus RTU
Output Power0.4-15kW
Output Frequency Range0 to 400 Hz
Overload Capacity150% for 60 seconds
Protection FeaturesOvercurrent, Overvoltage, Undervoltage, Overheating, Short Circuit
Operating Temperature-10°C to +50°C
Storage Temperature-20°C to +65°C
Humidity5 to 95% RH (non-condensing)
Supply Voltage200-240V AC (3-phase)