Page #70 background imageLoading...
Page #70 background image
u
Menu Structure for Digital LED Operator
XXXX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
X
:
:
:
:
Turn the power on
Forward Selection
Reverse Selection
Output Frequency
Output Current
Output Voltage
Monitor Display
Verify Menu
Set Up Mode
Parameter Setting Mode
Auto-Tuning
DRV light is on.
Pressing RUN will start the motor.
DRV light is off.
Drive cannot operate the motor.
Description of Key Operations
Note: “XX” characters are shown in this manual.
The drive will display the actual setting values.
PROGRAMMING MODE
DRIVE MODE
<1>
Figure 4.3 Digital LED Operator Screen Structure
<1> Reverse can only be selected when LOCAL is set.
4.2
Using the Digital LED Operator
SIEP C710606 20 OYMC AC Drive - V1000 User Manual
69
4
Start-Up Programming
& Operation
7/16/2008-13:23

Table of Contents

Other manuals for Omron V1000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron V1000 and is the answer not in the manual?

Omron V1000 Specifications

General IconGeneral
Cooling MethodFan cooling
Enclosure RatingIP20
CommunicationModbus RTU
Output Power0.4-15kW
Output Frequency Range0 to 400 Hz
Overload Capacity150% for 60 seconds
Protection FeaturesOvercurrent, Overvoltage, Undervoltage, Overheating, Short Circuit
Operating Temperature-10°C to +50°C
Storage Temperature-20°C to +65°C
Humidity5 to 95% RH (non-condensing)
Supply Voltage200-240V AC (3-phase)