Understanding the Hardware Components and Connections
“Cisco Catalyst 4948 Ethernet Management Switch” on page 26
“Power Distribution Units” on page 26
SPARC T5-8 Servers
The Full Rack version of Oracle SuperCluster T5-8 contains two SPARC T5-8 servers, each
with four processor modules. The Half Rack version of Oracle SuperCluster T5-8 also contains
two SPARC T5-8 servers, but each with two processor modules.
Redundancy in the SPARC T5-8 servers is achieved two ways:
Through connections between the servers (described in “Understanding the SPARC T5-8
Server Physical Connections” on page 26)
Through components within the SPARC T5-8 servers:
Fan modules – Each SPARC T5-8 server contains 10 fan modules. The SPARC T5-8
server will continue to operate at full capacity if one of the fan modules fails.
Disk drives – Each SPARC T5-8 server contains eight hard drives. Oracle SuperCluster
T5-8 software provides redundancy between the eight disk drives.
Processor modules – Oracle SuperCluster T5-8 contains two SPARC T5-8 servers.
For the Full Rack version of Oracle SuperCluster T5-8, each SPARC T5-8 server
contains four processor modules. There are two sockets or PCIe root complex pairs on
each processor module, where 16 cores are associated with each socket, for a total of
eight sockets or PCIe root complex pairs (128 cores) for each SPARC T5-8 server.
For the Half Rack version of Oracle SuperCluster T5-8, each SPARC T5-8 server
contains two processor modules. There are two sockets or PCIe root complex pairs on
each processor module, where 16 cores associated with each socket, for a total of four
sockets or PCIe root complex pairs (64 cores) for each SPARC T5-8 server.
Exadata Storage Servers
The Full Rack version of Oracle SuperCluster T5-8 contains eight Exadata Storage Servers.
The Half Rack version of Oracle SuperCluster T5-8 contains four Exadata Storage Servers.
Redundancy in the Exadata Storage Servers is achieved two ways:
Through connections between the Exadata Storage Servers. For more information, see
“Understanding the Exadata Storage Server Physical Connections” on page 36.
Through components within the Exadata Storage Servers:
Power supplies – Each Exadata Storage Server contains two power supplies. The
Exadata Storage Server can continue to operate normally if one of the power supplies
fail, or if one of the power distribution units fail.
24 Oracle SuperCluster T5-8 Owner's Guide • May 2016

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Oracle SuperCluster T5-8 and is the answer not in the manual?

Oracle SuperCluster T5-8 Specifications

General IconGeneral
BrandOracle
ModelSuperCluster T5-8
CategoryServer
LanguageEnglish

Related product manuals