EasyManuals Logo

Oracle SuperCluster T5-8 User Manual

Oracle SuperCluster T5-8
356 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #288 background imageLoading...
Page #288 background image
Preparing for Installation
Oracle Exadata Storage Expansion Full
Rack
Oracle Exadata Storage Expansion Half
Rack
Oracle Exadata Storage Expansion Quarter
Rack
- 600 GB 15 K RPM High Performance
SAS disks or 3 TB 7.2 K RPM High
Capacity SAS disks (first Exadata
Storage Server type)
or
- 1.2 TB 10 K RPM High Performance
SAS disks or 4 TB 7.2 K RPM High
Capacity SAS disks (second Exadata
Storage Server type)
3 Sun Datacenter InfiniBand Switch 36
High speed flash:
- 28.8 TB of raw flash capacity (first
Exadata Storage Server type)
or
- 57.6 TB of raw flash capacity (second
Exadata Storage Server type)
Keyboard, video, and mouse (KVM)
hardware
2 redundant 15 kVA PDU (single-phase
or three-phase, high voltage or low
voltage)
1 48-port Cisco Catalyst 4948, model
number WS-C4948-S Ethernet switch
- 600 GB 15 K RPM High Performance
SAS disks or 3 TB 7.2 K RPM High
Capacity SAS disks (first Exadata
Storage Server type)
or
- 1.2 TB 10 K RPM High Performance
SAS disks or 4 TB 7.2 K RPM High
Capacity SAS disks (second Exadata
Storage Server type)
3 Sun Datacenter InfiniBand Switch 36
High speed flash:
- 14.4 TB of raw flash capacity (first
Exadata Storage Server type)
or
- 28.8 TB of raw flash capacity (second
Exadata Storage Server type)
Keyboard, video, and mouse (KVM)
hardware
2 redundant 15 kVA PDUs (single-
phase or three-phase, high voltage or low
voltage)
1 48-port Cisco Catalyst 4948, model
number WS-C4948-S Ethernet switch
- 600 GB 15 K RPM High Performance
SAS disks or 3 TB 7.2 K RPM High
Capacity SAS disks (first Exadata
Storage Server type)
or
- 1.2 TB 10 K RPM High Performance
SAS disks or 4 TB 7.2 K RPM High
Capacity SAS disks (second Exadata
Storage Server type)
2 Sun Datacenter InfiniBand Switch 36
High speed flash:
- 6.4 TB of raw flash capacity (first
Exadata Storage Server type)
or
- 12.8 TB of raw flash capacity (second
Exadata Storage Server type)
Keyboard, video, and mouse (KVM)
hardware
2 redundant 15 kVA PDUs (single-
phase or three-phase, high voltage or low
voltage)
1 48-port Cisco Catalyst 4948, model
number WS-C4948-S Ethernet switch
In earlier releases, the high capacity disks were 2 TB.
For raw capacity, 1 GB = 1 billion bytes. Capacity calculated using normal space terminology of 1 TB = 1024 * 1024 * 1024 * 1024 bytes. Actual formatted
capacity is less.
Preparing for Installation
These topics provide information to prepare your site for the installation of the Oracle Exadata
Storage Expansion Rack. Planning for the expansion rack is similar to planning for Oracle
SuperCluster T5-8. This section contains information specific to the expansion rack, and also
refers to “Preparing the Site” on page 95 for general planning information.
“Reviewing System Specifications” on page 289
“Reviewing Power Requirements” on page 289
“Preparing for Cooling” on page 293
“Preparing the Unloading Route and Unpacking Area” on page 296
“Preparing the Network” on page 297
288 Oracle SuperCluster T5-8 Owner's Guide • May 2016

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Oracle SuperCluster T5-8 and is the answer not in the manual?

Oracle SuperCluster T5-8 Specifications

General IconGeneral
BrandOracle
ModelSuperCluster T5-8
CategoryServer
LanguageEnglish

Related product manuals