110 EVO Installation Guide
After entering the section corresponding to the desired message, use the Message Programming Keys (refer to
Table 8) and Table 7 on page 93 to change the message to suit your installation needs.
K641 Programming
C.0.7 Partition Assignment
SECTION [001]: OPTIONS [1] TO [8]
To assign the keypad to a partition, simply enable the option that corresponds to the desired partition. By
default, partitions 1 to 8 are enabled.
C.0.8 Display Access Code Entry
SECTION [003]: OPTION [1]
C.0.9 Display Exit Delay Timer
SECTION [003]: OPTION [2]
C.0.10 Display Entry Delay Timer
SECTION [003]: OPTION [3]
C.0.11 Confidential Mode
SECTION [003]: OPTIONS [4] AND [5]
In Confidential Mode, all LEDs will turn off and the display will change until either a button is pressed or an
access code is entered.
Figure 26: LCD Screen
C.0.12 Confidential Mode Timer
SECTION [007]
Section [007] determines the amount of time without action before the keypad enters Confidential Mode. The
Confidential Mode Timer can be set from 005 seconds to 255 seconds. Default: 120 seconds.
C.0.13 Time Display Option
SECTION [003]: OPTION [8]
Section [101] to [148] = “Zone 01” to “Zone 48” respectively
Section [200] = “Paradox Security”
Section [201] to [204] =
“First Area”, “Second Area”, “Third Area”,
and “Fourth Area” respectively
Section [301] to [396] = “Code 01” to “Code 96” respectively
O
ption [1] OFF = Digits are replaced by a * (default)
Option [1] ON = Access Code digits will be displayed
Option [2] OFF= Will not display Exit Delay timer (default)
Option [2] ON= LCD screen will display Exit Delay timer
Option [3] OFF= Will not display the Entry Delay Timer (default)
Option [3] ON= LCD screen will display Entry Delay Timer
Option [4] OFF = Normal Mode (default)
Option [4] ON = Confidential Mode
Option [5] OFF =
LCD screen activated by entering an access code
(default)
Option [5] ON = LCD screen activated by pressing a button
Option [8] OFF = Date displayed as yy/mm/dd (default)
Option [8] ON = Date displayed as dd/mm/yy