EVO Installation Guide 43
6.2.5 Generates a Utility Key Event on Open and Close
SECTIONS [0601] TO [0632]: FIRST DIGIT = 4
A Utility Key Event can be generated whenever the keyswitch input is opened or closed. The Utility Key Events
increase from 32 to 64 events; one event for each state.
When a keyswitch is defined with the Generate a Utility Key Event on Open and Close option, the Keyswitch
Partition Assignment and Keyswitch Options are disabled. To program a keyswitch to generate a Utility Key
Event:
1. Program the Activation Event of a PGM output with the Utility Key Event corresponding to the desired
keyswitch (see PGM Programming Table in the "EVO Programming Guide": Event Group 048).
2. Enable option [4] in the section corresponding to the desired keyswitch.
6.3 Keyswitch Partition Assignment
SECTIONS [0601] TO [0632]: SECOND DIGIT = 1 TO 8
Each keyswitch must be assigned to one partition.
6.4 Keyswitch Options
Each keyswitch zone can be programmed with one or more options.
6.4.1 Disarm Only
Sections [0601] to [0632]: Option [3]
When enabled, the keyswitch can only disarm assigned partitions. The type of disarming is determined by the
other Keyswitch Options selected.
6.4.2 Stay/Instant Disarm Option (Keyswitch)
SECTIONS [0601] TO [0632]: OPTION [4]
When enabled, the keyswitch can only disarm assigned Stay or Instant armed partitions. When option [4] is
disabled, the keyswitch can disarm partitions armed using any arming method.
6.4.3 Arm Only (Keyswitch)
SECTIONS [0601] TO [0632]: OPTION [5]
When enabled, the keyswitch can only arm assigned partitions. The type of arming is determined by the other
Keyswitch Options selected.
6.4.4 Regular Arming (Keyswitch)
SECTIONS [0601] TO [0632]: OPTION [6] TO [8]
With disabled, the arming option will be Regular arming.
6.4.5 Stay Arming (Keyswitch)
SECTIONS [0601] TO [0632]: OPTION [6]
Activating the keyswitch will Stay Arm the partition.
6.4.6 Force Arming (Keyswitch)
SECTIONS [0601] TO [0632]: OPTION [7]
Activating the keyswitch will force arm the selected partition.
6.4.7 Instant Arming (Keyswitch)
SECTIONS [0601] TO [0632]: OPTION [8]
This option is identical to Stay arming except that all armed zones will become Instant Zones.