EVO Installation Guide 53
7.4 Call Waiting Cancel
1. Section 4.5 requires a programmable option for call waiting cancel shall be required on communicators
that use media (e.g. PSTN) where call-waiting may be provisioned.
The programming for this feature must be added to the Programming Guide.
The installer needs to verify the code in the premises area for the telephone network that disables the call
waiting feature, then add it to the monitoring station number.
For example:
Receiving center phone number: 999-999-999
Call waiting cancelation code: *70
Phone number to program: *70P999999999
) Instructions that an automatic telephone dialer or similar device shall not be set or programmed to place a call
to a police station number that has not been specifically assigned by that police station for such service. The
instructions may be incorporated on the inside of the product, on a separate sheet, or as part of a manual. If not
included directly on the product, the instructions or manual shall be referenced in the marking information on
the product. .
Note: Do NOT program this system or any of its modules to automatically place a call to a police station
number that has not been specifically assigned by that police station for such a service.
7.5 Testing and Maintenance
7.5.1 Burglar Alarm Testing
Two people are needed to complete this test. One person will watch the screen on the keypad while the other
person walks around the protected areas and opens the zones.
(i.e. opens the doors and windows that are protected, walk in the path of the motion detectors, etc.). The screen
will display the opened zones, but if a zone does not register, contact your installer.
7.5.2 Fire Alarm Testing
Do NOT use an open flame or burning materials to test your fire detection devices. Your installer will provide
details on the best way to test your system.
7.5.3 System Maintenance
Under normal use your system requires no maintenance other than regular testing. We recommend that your
installer change the battery every three years.
7.5.4 System Test
Speak to your installer before conducting a System Test since the system must be programmed to respond to
the test instructions. It is normally recommended that you conduct the system test once a week, but contact
your installer for instructions concerning your particular system.
The system will test all its connections and can send a report to your monitoring station.
If the system detects a problem, the Trouble Display will show on the screen (refer to section 9.0 on page 19).
Call your installer for repairs if any troubles occur.
7.5.5 Replacement Parts
The following parts are replaceable.
1. Main backup battery must be a12Vdc 7Ah rechargeable acid/lead battery.