EVO Installation Guide 63
9.5.1 Tamper Bypass Options
SECTION [3034]: OPTION [7]
(default = enabled) When enabled in section [3034], the control panel will ignore the zone’s bypass definition
and will follow the option set in
section 9.5 (page 62) if a tamper or wire fault occurs on a bypassed zone. When
disabled, Tamper Recognition follows the zone’s bypass definition. This means that the control panel will not
perform any action if a tamper or wire fault occurs on a bypassed zone.
9.6 Keypad Panic Options
(default = disabled) The control panel can generate an alarm (audible, fire or report only) by pressing the
keypad Panic key(s). Refer to the table below for the keypad Panic keys. In the section that corresponds to the
desired partition, enable or disable options
[1] through [6]:
Report Only
The keypad emits a single confirmation beep and transmits the report code.
OFF OFF
Disabled (default):
Displays zone open on the keypads, but will not generate an alarm
or trouble.
Not permitted on UL systems.
OFF ON
Generates Trouble Only (when armed or disarmed):
The control panel displays Zone Fault in the Trouble Display and
transmits the defined report code (see section 10.2 on page 67).
ON OFF
When disarmed: Generates Trouble Only
The control panel displays Zone Fault in the
Trouble Display and transmits the defined report
code (see section 10.2 on page 67).
When armed: Follows Zone Alarm Type
The control panel follows the zone’s alarm type
(section 4.6.5 on page 36).
ON ON
When disarmed: Generates Audible Alarm
The control panel displays Zone Fault in the Trouble Display,
transmits the defined report code (see section 10.2 on page 67),
and generates an audible alarm.
When armed: Follows Zone Alarm Type
The control panel follows the zone’s alarm type (section 4.6.5 on
page 36).
Partition 1: [3123] Partition 3: [3323] Partition 5: [3523] Partition 7: [3723]
Partition 2: [3223] Partition 4: [3423] Partition 6: [3623] Partition 8: [3823]
Option
Feature Press and Hold 2 Seconds:
[1]
Panic 1*
LCD keypads: Keys [1] and [3] simultaneously
Grafica keypads: The key
[2]
Panic 2*
LCD keypads: Keys [4] and [6] simultaneously
Grafica keypads: The key
[3]
Panic 3
LCD keypads: Keys [7] and [9] simultaneously
Grafica keypads: The key
Option
Alarm Type
[4]
Panic 1:*
ON = Audible
OFF = Report Only
[5]
Panic 2:*
ON = Audible
OFF = Report Only
[6]
Panic 3:
ON = Fire
OFF = Report Only