EVO Installation Guide 77
10.17 Auto Report Code Programming
When using either the Contact ID or SIA Reporting Formats (see section 10.7 on page 73), the control panel
can automatically program a set of default report codes. The Contact ID Reporting Format can be modified
using the manual programming method (see
section 10.7.4 & see section 10.7.5 on page 74) to program
remaining report codes or to change some of the defaults. Enter any of the following sections to set the
indicated report codes with the default values (FF) from the Automatic Report Codes List in the "EVO
Programming Guide":
10.18 Closing Delinquency Timer
(default = 000; disabled) When a partition in the system is disarmed, the control panel will start the
corresponding partitionās Closing Delinquency Timer. If the Closing Delinquency Timer elapses before the
partition is armed again, EVO will transmit a āClosing Delinquencyā report code to the monitoring station. Enter
a value from 001 to 255 days into the appropriate section. Enter 000 to disable the Closing Delinquency Timer.
Sectio
n
Description
[4030] Resets all the report code sections to 00 (cleared).
[4031] Sets all the report code sections to FF (defaults).
Sectio
n
Sets to Defaults (FF) Reset Sections
[4032]
Zone Alarm and Restore Report Codes
Tamper and Restore Report Codes
[0201] to [0296]
[4033]
Keyswitch Arming Report Codes
Keyswitch Disarming Report Codes
Access Code Arming Report Codes
Access Code Disarming Report Codes
[0701] to [0732]
[0801] to [0832]
[2001] to [2099]
[2101] to [2199]
[4034] Special System Report Codes [3900] to [3909]
[4035]
Special Arming Report Codes
Special Disarming Report Codes
[3910] to [3919]
[3920] to [3929]
[4036] Special Alarm Report Codes [3930] to [3939]
[4037] Trouble and Restore Report Codes [3940] to [3991]
Partition 1: [3119] Partition 3: [3319] Partition 5: [3519] Partition 7: [3719]
Partition 2: [3219] Partition 4: [3419] Partition 6: [3619] Partition 8: [3819]